Fire Alarm Systems

Addressable Fire Alarm System

Addressable fire alarm system where each device has a unique address, allowing precise identification of fire location and faster response.

Components:

  • Addressable Fire Alarm Control Panel
  • Addressable Smoke Detector
  • Addressable Heat Detector
  • Addressable Manual Call Point
  • Addressable Monitor Module
  • Addressable Control Module
  • Addressable Annunciator

Conventional Fire Alarm System

Conventional fire alarm system designed to divide the protected area into zones. Each zone is connected to detectors and manual call points to identify the general location of fire.

Components:

  • Conventional Fire Alarm Control Panel (1 zone / 6–8 zones)
  • Conventional Smoke Detector
  • Conventional Heat Detector
  • Beam Smoke Detector
  • Manual Call Point / Pull Station
  • Fire Bell (6” & 8”)
  • Strobe Sounder

Fire Safety Solutions

Automatic Fire Extinguisher System

The system with sensitive hose, there are fire extinguisher body in which there is extinguishing substance and sensing hose. The sensing hose is pressurized with nitrogen gas to the extreme edge and it explodes from the point where it senses the flame and discharge the extinguishing substance, present inside the fire extinguisher body, to the area where fire starts by functioning as a nozzle. Because it activities by doing early sensing from a very small flame, it minimizes the level of damage given by a fire. The Usage areas of the systems with sensitive hose
  • It is used in place such as electric, electronic panel interiors,
  • Information technologies rooms, Cables under the raised floor, Mechanic rooms of yachts,
UPS rooms Telephone switchboard panels Automobile engines,
  • Engine parts of the armored vehicles,
  • Construction equipment etc

Fire Cabinets

1. Single Fire Cabinet

Properties:

  • 1.5 mm DKP metal sheet
  • 0.70 micron electrostatic powder coating
  • Colors: RAL 3020 red / RAL 9001 off white
  • Fire hose (20–30 m options)
  • 1” globe valve
  • Stainless steel hose reel
  • Optional glass / plexiglass

2. Double Fire Cabinet

Properties:

  • 1.5 mm metal construction
  • Hose diameter: 2.5”
  • Fire valve: 2.5”
  • Couplings included
  • Imported hinges & accessories
  • Optional glass cover

Fire Hydrant System

Hydrant system used by fire brigades to access water supply.

Features:

  • Ground-mounted water intake
  • Hose connection outlets
  • Automatic drainage system
  • Anti-freezing mechanism

Fire Protection Valves

Types:

  1. Gate Valve (OS&Y)
    • Pressure: 300 PSI
    • UL Listed / FM Approved
    • AWWA C515 standard
  2. Swing Check Valve
    • Prevents backflow
    • AWWA C508 standard
  3. Pressure Reducing Valve
    • Maintains constant downstream pressure

Fire Pump Sets

Fire protection pump systems designed to supply water at required pressure and flow in accordance with NFPA 20.

Types:

  1. End Suction Pump
    • Single stage centrifugal pump
    • Enclosed impeller
    • Horizontal volute casing
  2. Horizontal Split Case Pump
    • Axially split casing
    • Dual suction radial impeller
  3. Diesel Engine Fire Pump
    • 100% performance reliability
    • Used in absence of electrical supply
  4. Electric Motor Fire Pump
  5. Jockey Pump
    • Capacity: ~3% of main pump
    • Pressure: 110% of rated pressure
    • Maintains system pressure

Fire Rated Doors

Fire-rated doors designed to meet safety standards and prevent fire spread.

Types:

  • Fire Rated Steel Doors
  • Fire Rated Glazed Doors (Forster / Yawal Systems)
  • Rolling Shutter Fire Doors
  • Sliding Fire Doors
  • Acoustic & Bullet Proof Doors

Features:

  • 90-minute fire resistance
  • Fire-rated locks, handles, frames, and glass
  • Compliance with fire safety standards

Foam Fire Fighting System

Equipment:

  1. Foam Bladder Tank
    • Capacity: 140 – 15000 L
    • Pressure: 2.1 – 12 bar
    • Material: Carbon steel / Stainless steel
  2. Foam Chamber
    • UL Listed
    • Pressure: 2.8 – 7 bar
  3. Ratio Controller
    • Flow: 100 – 18500 LPM
    • Material: Bronze / Stainless steel
  4. Inline Inductor
    • Induction rate: 0–6%
    • Portable aluminum body

Foam Types:

  • AFFF
  • AR-AFFF
  • Fluoroprotein

Gas Suppression Systems

Types:

  1. CO2 System
    • Suitable for non-occupied areas
    • High efficiency fire suppression
  2. FM-200 System
    • Clean agent system
    • Safe for equipment and personnel

Installation & Maintenance

Fire System Installation & Maintenance

Complete installation and maintenance services for fire protection systems ensuring compliance with NFPA standards and reliable system performance.